Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Clinical Neurology ; (6): 294-296, 2017.
Article in Chinese | WPRIM | ID: wpr-615539

ABSTRACT

Objective To explore the significance of serum myoglobin detection in the diagnosis and evaluation of Kennedy`s disease (KD).Methods The level of serum myoglobin (Myo) was detected in 60 KD patients and 30 amyotrophic lateral sclerosis (ALS) patients.Results The serum Myo level and abnormal rate in KD group were significantly higher than those in ALS group (all P0.05).There was no overlap of serum Myo level between the two groups.There was no significant difference of serum Myo level and CAG repeated number of ALS (r=-0.193,P>0.05).Conclusion Myo is likely as an easy and sensitive biomarker, used to identify the KD and special type of ALS, and used in the evaluation of the KD condition in the future.

2.
Chinese Journal of Neurology ; (12): 298-301, 2015.
Article in Chinese | WPRIM | ID: wpr-469028

ABSTRACT

Objective To develop a scale to assess Kennedy's disease (KD) based on patients' clinical characteristics and to validate its application in patients.Methods We developed KD1234 Scale following the model of Amyotrophic Lateral Sclerosis-Functional Rating Scale.Using this new scale,we assessed patients with genetic diagnosis of KD and evaluated the reliability and validity of the new scale.Reliability was analyzed using Cronbach' s α coefficient and split-half reliability.Validity was analyzed by content validity and structure validity.Results The Cronbach' s α coefficient of the total scale was 0.789 and split-half reliability coefficient was 0.868.The α of breathing with total score was 0.3-0.4,α of written,language and swallowing with the total score was 0.4-0.5,α of other items with the total score was > 0.5 (P < 0.01 in each of above α).Four common factors extracted by exploratory factor analysis had well correspondence between the scale construction and the theoretical construction.Factor loading was ranged from 0.541 to 0.864 for each item.The duration of the disease showed some correlation with the score of KD1234 Scale.Conclusions The KD1234 Scale demonstrates high reliability and validity.The duration of the disease indicates negative correlation with KD1234 Scale scores.The KD1234 Scale can be used in clinical research to evaluate the condition of KD patients quantitatively.

SELECTION OF CITATIONS
SEARCH DETAIL